Skip to content

Releases: NatLabRockies/openstudio-standards

v0.8.6

24 Mar 21:10
a0d9052

Choose a tag to compare

Fixes some issues with openstudio-standards for ComStock:

  • Fix lookup error in pre-1980 PTHP standard efficiency lookups
  • Fix errors in create_bar if only one space type per story
  • Change default thermostat setpoint schedules for a range of building types, mostly back to their previous versions in ComStock
  • Change the default cooling thermostat setpoint in warehouse storage spaces from 80F to 85F.
  • Adjust building facade exterior lighting to use perimeter length instead of facade area. Use averages from NEEA data by building type to set default facade exterior lighting values.

What's Changed

Full Changelog: v0.8.5...v0.8.6

v0.8.5

05 Jan 19:57

Choose a tag to compare

This release refactors more methods into modules:

  • Add support for adding typical interior lighting in an interior lighting module
  • HVAC component refactor that moves component level methods into the HVAC module
  • Prototype space type mapping to translate old prototype building/space types into new openstudio-standards space types and setting additional properties
  • Several minor bug fixes.
  • NECB code update.

What's Changed

Full Changelog: v0.8.4...v0.8.5

v0.8.4

26 Sep 17:24

Choose a tag to compare

Minor bug fixes. Includes NECB updates.

What's Changed

  • Including boiler fuel type and capacity ratio changes, SHW fuel type changes, and changes from master. by @ckirney in #1833
  • Update from nrcan branch by @ckirney in #1850
  • Updates from nrcan to support VSCode and NREL Docker images by @ckirney in #1851
  • Merging changes from nrcan_434 by @ckirney in #1858
  • Including fix to missing system 6 air loops by @ckirney in #1862
  • Tweak a comment in test_dcv.rb just for the sake of re-running all te… by @ckirney in #1863
  • Update code to determine if HW loop is required for a Heating system. Removing support for TPFC systems for cooling only until code supports it. by @ckirney in #1867
  • Fixing type in boiler_fueltype parameter in noair baseboard ECM. by @ckirney in #1868
  • Pulling additional fixes when setting the system type by @ckirney in #1873
  • Update from nrcan branch by @ckirney in #1877
  • Including HS15 CASHP by @ckirney in #1879
  • Nrcan 434 by @ckirney in #1880
  • Including ability to force the system type used by TZs in the building. by @ckirney in #1884
  • Update with revised regression test results by @ckirney in #1885
  • Including changes to force hot-water fan coils in air loops if desired by @ckirney in #1892
  • Including carbon pricing in NPV calculation (#1899) by @ckirney in #1900
  • Nrcan by @ckirney in #1907
  • Include peak electric, electric heating, and electric water heating u… by @ckirney in #1908
  • Incorporating ECCC emission factors for natural gas and predicted emission factors for electricity grids. by @ckirney in #1910
  • nrcan_462: Two tasks: 1) Change control zone for system 4; 2) Change setpoint of hot-water loop in the HS14, HS15, and HS16 systems by @srgilani in #1960
  • Using heating requirement to determine the sys 4 control zone. Increasing the loop setpoint temperature to 60 C. Updating by @ckirney in #1964
  • Update necb_2011.rb by @ckirney in #1970
  • Adding try_sizing_run method to sizing run 2. Inculding sizing run s… by @ckirney in #1973
  • Merge thermal zone multiplier map fixes by @ckirney in #1977
  • Nrcan merge master by @ckirney in #1979
  • Nrcan merge master by @ckirney in #1980
  • Update which applies the local costing .csv files, fixing the costing issue by @ckirney in #1981
  • Including reference to costing csv files by @ckirney in #1983
  • Nrcan by @ckirney in #1985
  • Speed tests by @phylroy in #1986
  • Updating covert_arg_to_bool to work as intended by @ckirney in #1993
  • Updating covert_arg_to_bool to work as intended (#1993) by @ckirney in #1994
  • Nrcan merge master by @ckirney in #1995
  • Nrcan 460 merge by @ckirney in #2000
  • Nrcan merge os390 by @ckirney in #1988
  • log_messages_to_runner: allow passing custom exclusions by @jmarrec in #2011
  • Fix incorrect model call to unmet hours check in baseline PRM by @mdahlhausen in #2008
  • Fix broken generate_userdata_to_csv by @jmarrec in #2004
  • Fix #2006 - Do not instantiate unique model objects (SiteGroundTemperatureXXX) by @jmarrec in #2007
  • #2009 - Ground condition error handling by @jmarrec in #2010

Full Changelog: v0.8.3...v0.8.4

v0.8.3

26 Aug 15:10

Choose a tag to compare

Minor release with changes to standards data and bug fixes. Improves modeling of typical refrigeration and service water heating.

What's Changed

Full Changelog: v0.8.2...v0.8.3

v0.8.2

18 Jun 03:25
eac3805

Choose a tag to compare

What's Changed

Full Changelog: v0.8.1...v0.8.2

v0.8.1

14 Jun 23:45
bef4b49

Choose a tag to compare

Add some additional features for ComStock report and address highly requested weather file issue.

What's Changed

Full Changelog: v0.8.0...v0.8.1

v0.8.0

05 Jun 18:53
d9b691f

Choose a tag to compare

This release moves space type data for infiltration, service water heating, exhuast fans, and refrigeration into modules. It adds an exterior lighting module with typical building assumptions. It incorporates new refrigeration data from ORNL's refrigeration database and adds support for grocery stores to create typical workflows.

What's Changed

New Contributors

Full Changelog: v0.7.1...v0.8.0

v0.7.1

13 Dec 22:31

Choose a tag to compare

A patch release with a bug fix to #1864
Full Changelog: v0.7.0...v0.7.1

v0.7.0

05 Nov 18:31

Choose a tag to compare

This release adds the ServiceWaterHeating module and fixes several bugs.

What's Changed

Full Changelog: v0.6.3...v0.7.0

v0.6.3

04 Sep 15:20
e61d7d4

Choose a tag to compare

This is a minor release with bugs fixes and updates to create typical and geometry module methods used in ComStock.

What's Changed

New Contributors

Full Changelog: v0.6.2...v0.6.3