# DEVICE:COMMENT:
2+
# Device dump generated by ./nut-ddl-dump.sh on Wed, 26 Nov 2025 21:26:38 +0200
3+
# DEVICE:EOC
4+
5+
# :; upsc Eaton9E2000i@127.0.0.1
6+
battery.capacity: 7.00
7+
battery.charge: 100
8+
battery.charge.low: 20
9+
battery.charge.restart: 0
10+
battery.charger.type: Constant Charge (CC)
11+
battery.protection: yes
12+
battery.runtime: 3353
13+
battery.runtime.low: 180
14+
battery.type: PbAc
15+
battery.voltage: 83.0
16+
battery.voltage.nominal: 72
17+
device.mfr: EATON
18+
device.model: 9E2000i
19+
device.serial: GE16F43216
20+
device.type: ups
21+
device.usb.version: 01.29
22+
driver.debug: 0
23+
driver.flag.allow_killpower: 0
24+
driver.name: usbhid-ups
25+
driver.parameter.interrupt_pipe_no_events_tolerance: -1
26+
driver.parameter.pollfreq: 30
27+
driver.parameter.pollinterval: 2
28+
driver.parameter.port: auto
29+
driver.parameter.synchronous: auto
30+
driver.state: quiet
31+
driver.version: 2.8.4.787-787+gf8ecd520a
32+
driver.version.data: MGE HID 1.57
33+
driver.version.internal: 0.71
34+
driver.version.usb: libusb-1.0.29 (API: 0x0100010A)
35+
experimental.ups.mode.buzzwords: vendor:mge-hid:ECO vendor:default:ECO
36+
input.bypass.frequency: 49.9
37+
input.bypass.switch.off: disabled
38+
input.bypass.switch.on: disabled
39+
input.bypass.switchable: enabled
40+
input.bypass.voltage: 235.0
41+
input.eco.switchable: ECO
42+
input.frequency: 49.9
43+
input.frequency.nominal: 50
44+
input.transfer.bypass.forced: enabled
45+
input.transfer.bypass.high: 264
46+
input.transfer.bypass.low: 184
47+
input.transfer.bypass.overload: enabled
48+
input.transfer.eco.high: 243
49+
input.transfer.eco.low: 218
50+
input.transfer.frequency.bypass.range: 10
51+
input.transfer.frequency.eco.range: 5
52+
input.transfer.high: 300
53+
input.transfer.hysteresis: 10
54+
input.transfer.low: 100
55+
input.voltage: 235.0
56+
input.voltage.nominal: 235
57+
outlet.1.designator: AC OUTPUT
58+
outlet.1.protect.status: protected
59+
outlet.1.status: on
60+
outlet.desc: Main Outlet
61+
outlet.id: 0
62+
outlet.switchable: no
63+
output.current: 1.40
64+
output.frequency: 49.9
65+
output.frequency.nominal: 50
66+
output.voltage: 236.0
67+
output.voltage.nominal: 230
68+
ups.beeper.status: enabled
69+
ups.delay.shutdown: 20
70+
ups.delay.start: 30
71+
ups.firmware: 00.02.000
72+
ups.load: 17
73+
ups.load.high: 105
74+
ups.mfr: EATON
75+
ups.model: 9E2000i
76+
ups.power: 340
77+
ups.power.nominal: 2000
78+
ups.productid: ffff
79+
ups.realpower: 296
80+
ups.realpower.nominal: 1600
81+
ups.serial: GE16F43216
82+
ups.shutdown: enabled
83+
ups.start.auto: yes
84+
ups.start.battery: yes
85+
ups.start.reboot: yes
86+
ups.status: OL
87+
ups.temperature: 24.9
88+
ups.test.interval: 604800
89+
ups.test.result: Done and passed
90+
ups.timer.shutdown: -1
91+
ups.timer.start: -1
92+
ups.type: online
93+
ups.vendorid: 0463
94+
95+
# DEVICE:COMMENT-BLOCK:FIXME:UPSRW: Eaton9E2000i@127.0.0.1
96+
# [battery.charge.low]
97+
# Remaining battery level when UPS switches to LB (percent)
98+
# Type: STRING
99+
# Maximum length: 5
100+
# Value: 20
101+
#
102+
# [battery.charge.restart]
103+
# Minimum battery level for restart after power off (percent)
104+
# Type: STRING
105+
# Maximum length: 3
106+
# Value: 0
107+
#
108+
# [battery.protection]
109+
# Prevent deep discharge of battery
110+
# Type: STRING
111+
# Maximum length: 5
112+
# Value: yes
113+
#
114+
# [battery.runtime.low]
115+
# Remaining battery runtime when UPS switches to LB (seconds)
116+
# Type: STRING
117+
# Maximum length: 10
118+
# Value: 180
119+
#
120+
# [driver.debug]
121+
# Current debug verbosity level of the driver program
122+
# Type: NUMBER
123+
# Value: 0
124+
#
125+
# [driver.flag.allow_killpower]
126+
# Safety flip-switch to allow the driver daemon to send UPS shutdown command (accessible via driver.killpower)
127+
# Type: NUMBER
128+
# Value: 0
129+
#
130+
# [input.bypass.switch.off]
131+
# Take the UPS out of Bypass mode
132+
# Type: STRING
133+
# Maximum length: 12
134+
# Value: disabled
135+
#
136+
# [input.bypass.switch.on]
137+
# Put the UPS in Bypass mode
138+
# Type: STRING
139+
# Maximum length: 8
140+
# Value: disabled
141+
#
142+
# [input.bypass.switchable]
143+
# Input auto transfer on Bypass when overload or out of tolerance (enabled or disabled)
144+
# Type: STRING
145+
# Maximum length: 8
146+
# Value: enabled
147+
#
148+
# [input.eco.switchable]
149+
# Input High Efficiency (aka ECO) mode switch
150+
# Type: STRING
151+
# Maximum length: 8
152+
# Value: ECO
153+
#
154+
# [input.transfer.bypass.forced]
155+
# Rule for allow auto Bypass switch (on/off) transfer modes (enabled or disabled)
156+
# Type: STRING
157+
# Maximum length: 8
158+
# Value: enabled
159+
#
160+
# [input.transfer.bypass.high]
161+
# High voltage Bypass transfer point (V)
162+
# Type: STRING
163+
# Maximum length: 5
164+
# Value: 264
165+
#
166+
# [input.transfer.bypass.low]
167+
# Low voltage Bypass transfer point (V)
168+
# Type: STRING
169+
# Maximum length: 5
170+
# Value: 184
171+
#
172+
# [input.transfer.bypass.overload]
173+
# Rule for auto transfer on Bypass when overload (enabled or disabled)
174+
# Type: STRING
175+
# Maximum length: 8
176+
# Value: enabled
177+
#
178+
# [input.transfer.eco.high]
179+
# High voltage ECO transfer point (V)
180+
# Type: STRING
181+
# Maximum length: 5
182+
# Value: 243
183+
#
184+
# [input.transfer.eco.low]
185+
# Low voltage ECO transfer point (V)
186+
# Type: STRING
187+
# Maximum length: 5
188+
# Value: 218
189+
#
190+
# [input.transfer.frequency.bypass.range]
191+
# Frequency range Bypass transfer point (percent of nominal Hz)
192+
# Type: STRING
193+
# Maximum length: 5
194+
# Value: 10
195+
#
196+
# [input.transfer.frequency.eco.range]
197+
# Frequency range ECO transfer point (percent of nominal Hz)
198+
# Type: STRING
199+
# Maximum length: 5
200+
# Value: 5
201+
#
202+
# [input.transfer.high]
203+
# High voltage transfer point (V)
204+
# Type: STRING
205+
# Maximum length: 5
206+
# Value: 300
207+
#
208+
# [input.transfer.hysteresis]
209+
# Threshold of switching protection modes, voltage transfer point (V)
210+
# Type: STRING
211+
# Maximum length: 5
212+
# Value: 10
213+
#
214+
# [input.transfer.low]
215+
# Low voltage transfer point (V)
216+
# Type: STRING
217+
# Maximum length: 5
218+
# Value: 100
219+
#
220+
# [outlet.desc]
221+
# Outlet description
222+
# Type: STRING
223+
# Maximum length: 20
224+
# Value: Main Outlet
225+
#
226+
# [output.voltage.nominal]
227+
# Nominal output voltage (V)
228+
# Type: ENUM STRING
229+
# Maximum length: 3
230+
# Option: "200"
231+
# Option: "208"
232+
# Option: "220"
233+
# Option: "230" SELECTED
234+
# Option: "240"
235+
#
236+
# [ups.delay.shutdown]
237+
# Interval to wait after shutdown with delay command (seconds)
238+
# Type: STRING
239+
# Maximum length: 10
240+
# Value: 20
241+
#
242+
# [ups.delay.start]
243+
# Interval to wait before (re)starting the load (seconds)
244+
# Type: STRING
245+
# Maximum length: 10
246+
# Value: 30
247+
#
248+
# [ups.load.high]
249+
# Load when UPS switches to overload condition (percent)
250+
# Type: STRING
251+
# Maximum length: 5
252+
# Value: 105
253+
#
254+
# [ups.shutdown]
255+
# Enable or disable UPS shutdown ability (poweroff)
256+
# Type: ENUM STRING
257+
# Maximum length: 10
258+
# Option: "disabled"
259+
# Option: "enabled" SELECTED
260+
#
261+
# [ups.start.auto]
262+
# UPS starts when mains is (re)applied
263+
# Type: STRING
264+
# Maximum length: 5
265+
# Value: yes
266+
#
267+
# [ups.start.battery]
268+
# Allow to start UPS from battery
269+
# Type: STRING
270+
# Maximum length: 5
271+
# Value: yes
272+
#
273+
# [ups.start.reboot]
274+
# UPS reboots when power returns during shutdown delay
275+
# Type: STRING
276+
# Maximum length: 5
277+
# Value: yes
278+
#
279+
# [ups.test.interval]
280+
# Interval between self tests (seconds)
281+
# Type: STRING
282+
# Maximum length: 8
283+
# Value: 604800
284+
# DEVICE:EOC
285+
286+
# DEVICE:COMMENT-BLOCK:FIXME:UPSCMD: Eaton9E2000i@127.0.0.1
287+
# Instant commands supported on UPS [Eaton9E2000i]:
288+
#
289+
# beeper.disable - Disable the UPS beeper
290+
# beeper.enable - Enable the UPS beeper
291+
# beeper.mute - Temporarily mute the UPS beeper
292+
# beeper.off - Obsolete (use beeper.disable or beeper.mute)
293+
# beeper.on - Obsolete (use beeper.enable)
294+
# bypass.start - Put the UPS in Bypass mode
295+
# bypass.stop - Take the UPS out of Bypass mode
296+
# driver.killpower - Tell the driver daemon to initiate UPS shutdown; should be unlocked with driver.flag.allow_killpower option or variable setting
297+
# driver.reload - Reload running driver configuration from the file system (only works for changes in some options)
298+
# driver.reload-or-error - Reload running driver configuration from the file system (only works for changes in some options); return an error if something changed and could not be applied live (so the caller can restart it with new options)
299+
# driver.reload-or-exit - Reload running driver configuration from the file system (only works for changes in some options); exit the running driver if something changed and could not be applied live (so service management framework can restart it with new options)
300+
# experimental.bypass.ecomode.start - Put UPS in Bypass mode then High Efficiency (aka ECO) mode
301+
# experimental.bypass.ecomode.stop - Take the UPS out of High Efficiency (aka ECO) mode after exiting Bypass mode
302+
# experimental.ecomode.start - Put UPS in High Efficiency (aka ECO) mode
303+
# experimental.ecomode.stop - Take the UPS out of High Efficiency (aka ECO) mode
304+
# experimental.essmode.start - Put UPS in Energy Saver System (aka ESS) mode
305+
# experimental.essmode.stop - Take the UPS out of Energy Saver System (aka ESS) mode
306+
# load.off - Turn off the load immediately
307+
# load.off.delay - Turn off the load with a delay (seconds)
308+
# load.on - Turn on the load immediately
309+
# load.on.delay - Turn on the load with a delay (seconds)
310+
# shutdown.default - Run the driver-defined UPS shutdown sequence (as opposed to user-configured 'sdcommands')
311+
# shutdown.return - Turn off the load and return when power is back
312+
# shutdown.stayoff - Turn off the load and remain off
313+
# shutdown.stop - Stop a shutdown in progress
314+
# test.battery.start.deep - Start a deep battery test
315+
# test.battery.start.quick - Start a quick battery test
316+
# test.battery.stop - Stop the battery test
317+
# DEVICE:EOC