function SaveRecording(SaveDirectory,RecordingName,ModuleInformation,TransducerInformation,ChannelSetup,GeneratorSetup,InterpretationMessages,SignalDataMessages,SampleRate,NumberOfSignalDataMessagesReceived)
% Bruel & Kjaer LAN-XI Open Application Programming Interface
% MATLAB Simple Recorder GUI Version 1.0 (September 15, 2021)
% By Matthew Houtteman and Gert Nyrup
% +1 800-332-2040
% Developed in MATLAB R2021a with LAN-XI Firmware 2.10.0.501
% This function saves the measurements as a .mat file
SignalDataMessagesPerChannel = min(NumberOfSignalDataMessagesReceived);
InterpretationMessages = sortrows(InterpretationMessages,{'ModuleNumber','SignalId'},{'ascend','ascend'});
SignalDataMessages = sortrows(SignalDataMessages,{'ModuleNumber','SignalId','Ticks'},{'ascend','ascend','ascend'});
for ii=1:1:height(SignalDataMessages)
TicksPerSecond = 2^double(SignalDataMessages.K(ii))*3^double(SignalDataMessages.L(ii))*5^double(SignalDataMessages.M(ii))*7^double(SignalDataMessages.N(ii));
SignalDataMessages.TickSecondsRelativeTime(ii) = (1/TicksPerSecond)*double(SignalDataMessages.Ticks(ii));
end
SignalDataMessages.TickSecondsRelativeTime = SignalDataMessages.TickSecondsRelativeTime - min(SignalDataMessages.TickSecondsRelativeTime);
varNames = ["ModuleNumber","ChannelNumber","ChannelName","t0","SignalData","Units"];
varTypes = ["double","double","string","datetime","cell","string"];
RecordingData = table('Size',[length(InterpretationMessages.SignalId) 6],'VariableTypes',varTypes,'VariableNames',varNames);
for ii=1:1:length(InterpretationMessages.SignalId)
RecordingData.ModuleNumber(ii) = double(InterpretationMessages.ModuleNumber(ii));
RecordingData.ChannelNumber(ii) = double(InterpretationMessages.SignalId(ii));
RecordingData.ChannelName(ii) = string(ChannelSetup{RecordingData.ModuleNumber(ii),1}.channels(RecordingData.ChannelNumber(ii)).name);
TableRowNumbers = SignalDataMessages.ModuleNumber == RecordingData.ModuleNumber(ii) & SignalDataMessages.SignalId == RecordingData.ChannelNumber(ii);
TempSignalDataMessages = SignalDataMessages(TableRowNumbers,:);
TempSignalDataMessages = TempSignalDataMessages(1:SignalDataMessagesPerChannel,:); %this line ensures the same number of signal data messages for all measurement channels
RecordingData.t0(ii) = string(FrontEndClock(TempSignalDataMessages.K(1),TempSignalDataMessages.L(1),TempSignalDataMessages.M(1),TempSignalDataMessages.N(1),TempSignalDataMessages.Ticks(1)));
Signal = zeros(length(TempSignalDataMessages.Values{1,1})*height(TempSignalDataMessages),1);
DataIndex = 1;
for jj = 1:1:height(TempSignalDataMessages)
Signal(DataIndex:1:(length(TempSignalDataMessages.Values{1,1})+DataIndex-1),1) = TempSignalDataMessages.Values{jj,1};
DataIndex = DataIndex + length(TempSignalDataMessages.Values{1,1});
end
RecordingData.SignalData{ii} = Signal;
RecordingData.Units(ii) = string(ChannelSetup{RecordingData.ModuleNumber(ii),1}.channels(RecordingData.ChannelNumber(ii)).transducer.unit);
clearvars Signal DataIndex
end
RelativeTime = 0:1/SampleRate:(length(RecordingData.SignalData{1,1})-1)/SampleRate;
FrequencyRange = SampleRate / 2.56; % usable frequency span in units of Hz
save(strcat(SaveDirectory,"\",RecordingName,".mat"),'ModuleInformation','TransducerInformation','ChannelSetup','GeneratorSetup','RecordingData','RelativeTime','SampleRate','FrequencyRange','-v7.3','-nocompression'); % optionally add in the following variables if desired for learning/development purposes: 'InterpretationMessages','SignalDataMessages','NumberOfSignalDataMessagesReceived','SignalDataMessagesPerChannel'
end