A reusable block is a verified schematic fragment that EasyEDA Copilot can find, adapt and insert into a generated circuit. It is useful for repeated standard solutions: DC/DC converters, LDO blocks, level shifters, sensor front ends, interfaces, filters, protection circuits and other blocks where the topology stays the same, but several values or external connections change from project to project.
The core idea is simple: create a good reference schematic once, describe its ports and recalculation parameters, then save it as a reusable block. Later, the AI agent can find this block, select it for a suitable task, recalculate allowed values and connect it to the rest of the circuit.
Reusable blocks give the agent a known-good starting point instead of forcing it to synthesize every common circuit from scratch.
Benefits:
- Higher reliability: the agent reuses a reviewed schematic topology instead of inventing it every time.
- Lower hallucination risk: critical circuit fragments can come from reusable, reviewed blocks.
- Faster generation: a whole subcircuit is selected and adapted as one unit.
- Consistent schematic style: repeated solutions keep the same component choices, naming and organization.
- Parameter adaptation: passive values can be recalculated for the requested voltage, current, frequency or other declared parameters.
The agent can still build a circuit manually if no suitable reusable block exists.
Recalculation is intended for passive components:
- resistors;
- capacitors;
- inductors.
Active components, ICs, connectors and mechanical elements should normally stay fixed. If a block needs another IC or another topology, create a separate reusable block or let the agent design that part manually.
Each block contains:
- name and description: what the block does and when to use it;
- category and tags: how the block is grouped and discovered;
- ports: external nets such as
VIN,VOUT,GND,EN,SCL,SDA; - parameters: numeric values such as
VIN,VOUT,ILOAD,FREQ; - component recalculation formulas: rules for passive values that change when parameters change;
- LCSC query templates: search text for finding a suitable replacement passive part after recalculation.
Clear metadata improves block discovery, so the name, description, category and tags should describe the real function and likely user requests.
When reusable blocks are enabled in settings, the circuit-making agent can use them for standard subcircuits. It should prefer a suitable reusable block over designing the same standard block manually.
When a reusable block is used, Copilot:
- Applies the parameters requested by the agent.
- Checks that changed parameters are allowed to be recalculated.
- Checks
minandmaxbounds when they are defined. - Replaces port templates with real net names.
- Evaluates formulas for recalculated components.
- Updates component values and search queries.
- Adds the resulting subcircuit to the generated schematic.
If the agent does not connect a port, Copilot assigns it an internal NC_* net so it does not accidentally connect to another signal.
First, create the standard circuit in EasyEDA. Choose a topology that is worth reusing and has clear external connections.
Good candidates:
- reference designs from datasheets;
- already verified project fragments;
- internal templates used repeatedly across boards;
- blocks where adaptation only requires changing passive values.
Before export, make sure external connections have meaningful net names. For example, VIN, VOUT, GND, EN, SCL, SDA are much easier to map than anonymous nets.
In EasyEDA, open:
Copilot -> Reused blocks -> Export
The reusable block editor has two main tabs:
Browse: read-only list of existing reusable blocks;Export: editor for creating a new reusable block.
In the Export tab, click Load from EasyEDA. The editor reads the current schematic and fills the component list.
You can also use Load from file if you already have a JSON export, and Save to file to keep an intermediate draft before saving the block.
Set:
- Block Name: concise technical name, for example
LM2596 buck converter. - Description: topology, main IC, intended use and operating range.
- Category: broad group such as
power-managementorcommunication-interfaces. - Tags: specific labels such as
buck-converter,ldo-regulator,i2c-interface.
Search uses this text, so avoid vague descriptions like "power circuit". Prefer phrases that a user or agent would actually search for: "3.3 V buck converter", "RS-485 transceiver interface", "I2C bidirectional level shifter".
Ports are the block's external connection points. Add every signal that the generated circuit may need to connect.
Typical examples:
- power block:
VIN,VOUT,GND,EN,PGOOD; - I2C level shifter:
VCCA,VCCB,SDA_A,SCL_A,SDA_B,SCL_B,GND; - op-amp filter:
IN,OUT,VCC,VEE,GND.
In component pins, bind nets to ports with templates:
{PORT_VIN}
{PORT_VOUT}
{PORT_GND}
All identical signal_name values are replaced together. This is how the agent connects the block to project nets such as +12V_IN, +3V3, MCU_I2C_SDA or GND.
Parameters are numeric values that describe operating conditions or design targets.
Each parameter has:
- Min: optional lower bound;
- Nominal: value used by the current reference schematic;
- Max: optional upper bound;
- Allow recalc: whether the AI agent may change this parameter.
Examples:
| Parameter | Meaning | Allow recalc |
|---|---|---|
VIN |
input voltage | sometimes |
VOUT |
output voltage | yes |
ILOAD |
output current | sometimes |
FREQ |
switching frequency | only if formulas and components support it |
Enable Allow recalc only when the formulas and selected components really support the whole declared range.
For every passive component that should change with parameters, add recalculation metadata:
- Formula: mathematical expression using
PARAM_variables and current component values. - Unit: measurement unit appended to the computed value.
- LCSC Query Template: search text used to find the replacement component.
Example for a feedback resistor:
formula: 100 * (PARAM_VOUT / 1.23 - 1)
unit: kOhm
lcsc_query_template: resistor {value} smd 0603 1%
Available values include:
PARAM_VOUT,PARAM_VOUT_min,PARAM_VOUT_max;PARAM_VIN,PARAM_ILOADand other declared parameters;- numeric component values such as
R1,C2,L1, extracted from their currentvalue; - component string fields as template variables, for example
{R1_value}.
The calculated result must be positive. Copilot formats it with two decimal places and appends the unit, for example 12.34kOhm.
Auto fill with AI can generate:
- block name and description;
- category and tags;
- ports;
- parameters and ranges;
- signal renaming operations;
- component recalculation formulas.
Treat this as a draft. Always review the result, especially:
- whether every external net is mapped to the correct
{PORT_*}; - whether
minandmaxranges are realistic; - whether
allow_recalcis enabled only where it is safe; - whether formulas match the datasheet;
- whether LCSC query templates include package, tolerance, voltage rating or power rating when required.
Click Add to database to save the reusable block.
Review the saved block before relying on it in generated circuits.
Open Copilot -> Reused blocks and use the Browse tab.
The browser shows:
- total number of blocks;
- current page;
- category and tags;
- component count and parameter names.
You can download:
- block data for review or backup;
- circuit assembly data for schematic inspection.
In Copilot settings, enable:
Add reused block to agent tools (Beta)
After this, the circuit-making agent can use reusable blocks. For standard units, it is instructed to prefer a suitable reusable block over manual design of the same subcircuit. In the generated result UI, used blocks are shown in the Reused blocks section with their name, category and tags.
- Keep one block focused on one clear function.
- Write clear metadata because it directly affects block discovery.
- Prefer reference circuits from datasheets.
- Do not expose internal nets as ports.
- Use stable, semantic port names.
- Keep parameter ranges conservative.
- Recalculate only the minimum necessary set of passive components.
- Include package, tolerance, voltage/current rating or power rating in LCSC query templates when it matters.
- Save a file draft before adding complex blocks.
- Test the block with a small prompt before relying on it in larger circuits.
- Wrong port template: a net was not renamed to
{PORT_*}, so the agent cannot connect the block correctly. - Too many recalculable parameters: the block looks flexible, but formulas do not cover the whole range.
- Weak description: Copilot cannot match the block to natural-language user requests.
- Units inside formulas: formulas operate on numbers; the unit is appended separately.
- Expecting active component replacement: recalculation does not change the IC or block topology.
Before saving, verify:
- metadata describes the real circuit and likely search phrases;
- all external nets are modeled as ports;
- all ports are used in
signal_namethrough templates; - every recalculable parameter has realistic bounds;
- formulas are checked against the datasheet;
recalcis used only for passive components;- LCSC queries are specific enough to find suitable parts;
- the block is reviewed before agent use.