Overview

The Opc.Ua.Client and Opc.Ua.Client.ComplexTypes libraries provide support for handling custom data types (complex types) in OPC UA client applications. Complex types include:

  • Custom Structures: User-defined structured data types with multiple fields
  • Custom Enumerations: User-defined enumeration types with custom values

The library allows OPC UA clients to automatically discover, load, and work with server-specific custom types, enabling seamless reading and writing of structured data without manual type definitions.

Key Concepts

What are Complex Types?

In OPC UA, complex types are custom data types defined by the server that extend beyond the built-in OPC UA data types. These types are commonly used to represent structured data such as:

  • Configuration structures with multiple parameters
  • Device status information with multiple fields
  • Custom enumerations specific to a domain or device

Type Discovery and Loading

The ComplexTypeSystem class manages the discovery and loading of custom types from an OPC UA server. It:

  1. Browses the server's type system to discover custom types
  2. Loads type definitions (using DataTypeDefinition attribute or binary/XML dictionaries)
  3. Registers types complying to the type definitions in the session's type factory for encoding/decoding

Supported Type Systems

The library supports multiple type definition mechanisms:

  • OPC UA 1.04+ DataTypeDefinition Attribute: Modern structured type definitions
  • OPC UA 1.03 Binary Schema Dictionaries: Legacy binary type dictionaries
  • OPC UA 1.03 XML Schema Dictionaries: Legacy XML type dictionaries

The library automatically uses the most appropriate mechanism available on the server.

Getting Started

Type builders

Default type builder

A type builder builds the types that are registered in the EncodeableFactory by the ComplexTypeSystem class. The default type builder registers in memory IEncodeable "adapter" classes that wrap discovered DataTypeDefinition and provide "state" (a list of Variants for the properties) clone, compare, and encode/decode behavior. The default type builder is part of the Opc.Ua.Core.Schema library (namespace Opc.Ua) and is shared by client and server. It is used when no type builder is provided in the constructor of the ComplexTypeSystem class.

Reflection.Emit based type builder

The OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes nuget package extends the Opc.Ua.Client library by adding a type builder implementation that supports dynamically generating .NET types via Reflection.Emit at runtime. This has the added benefit over the default approach that the types can be reflected over by other tools, e.g. serializers. However, this is not NativeAOT compliant, and therefore building against a NativeAOT runtime will always fall back to the default behavior.

To use the Reflection.Emit type builder add the NuGet package to your project:

dotnet add package OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes

Or via Package Manager:

Install-Package OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes

Basic Usage

1. Loading All Custom Types from a Server

The most common approach is to load all custom types after establishing a session:

using Opc.Ua;                     // ComplexTypeSystem, IComplexTypeResolver, default type builder
using Opc.Ua.Client;
using Opc.Ua.Client.ComplexTypes; // client Create(...) helpers + NodeCacheResolver

// Create and connect session
var session = await Session.Create(...);

// Create and load the complex type system
ComplexTypeSystem complexTypeSystem;
if (!useReflectionEmitTypeBuilder)
{
    // Uses the default (NativeAOT friendly) type builder
    complexTypeSystem = ComplexTypeSystem.Create(session, session.MessageContext.Telemetry);
}
else
{
    // Uses the Reflection.Emit type builder. Only works if the
    // OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes nuget is referenced.
    complexTypeSystem = ComplexTypeSystem.Create(
        session, new ComplexTypeBuilderFactory(), session.MessageContext.Telemetry);
}

await complexTypeSystem.LoadAsync();

Console.WriteLine($"Loaded {complexTypeSystem.GetDefinedTypes().Count} custom types");

After loading, the session can automatically encode and decode custom types when reading or writing values.

2. Reading Values with Complex Types

Once the type system is loaded, reading complex type values is straightforward:

// Read a value that contains a complex type
NodeId nodeId = new NodeId("ns=2;s=MyCustomStructVariable");
DataValue dataValue = await session.ReadValueAsync(nodeId);

// The value is automatically decoded to a .NET type
// Note: DataValue.Value is obsolete. Use WrappedValue (Variant) instead.
if (dataValue.WrappedValue.TryGetValue(out ExtensionObject extensionObject))
{
    // Access the structured data
    if (extensionObject.Body is IStructure complexType)
    {
        // Access properties by name
        Variant temperatureValue = complexType["Temperature"];
        Variant pressureValue = complexType["Pressure"];

        Console.WriteLine($"Temperature: {temperatureValue}");
        Console.WriteLine($"Pressure: {pressureValue}");

        // Enumerate all properties
        foreach (IStructureField property in complexType.GetFields())
        {
            Console.WriteLine($"{property.Name}: {complexType[property.Name]}");
        }
    }
}

3. Writing Values with Complex Types

To write complex type values, modify the properties and write back:

// Read current value
DataValue dataValue = await session.ReadValueAsync(nodeId);
dataValue.WrappedValue.TryGetValue(out ExtensionObject extensionObject);
var complexType = (IStructure)extensionObject.Body;

// Modify properties
complexType["Temperature"] = 25.5;
complexType["Pressure"] = 101.3;

// Write the modified value back
var writeValue = new WriteValue
{
    NodeId = nodeId,
    AttributeId = Attributes.Value,
    Value = new DataValue
    {
        WrappedValue = extensionObject,
        SourceTimestamp = DateTime.UtcNow
    }
};

var writeValues = new WriteValueCollection { writeValue };
var response = await session.WriteAsync(null, writeValues, CancellationToken.None);

if (StatusCode.IsGood(response.Results[0]))
{
    Console.WriteLine("Value written successfully");
}

Approaches for Working with Custom Types

There are three ways to work with custom data types from an OPC UA server. The right approach depends on your use case.

Approach 1: Hand-Written IEncodeable + EncodeableFactory Registration

If you have already implemented (or generated) a class that implements IEncodeable, you can register it with the session's EncodeableFactory. The stack will then automatically decode incoming ExtensionObject values into instances of your type.

Step 1 – Implement IEncodeable

// Required namespaces:
// using Opc.Ua;
// using System.Runtime.Serialization;

[DataContract(Namespace = "http://www.siemens.com/simatic-s7-opcua")]
public class UDT_SemVer : IEncodeable
{
    public UDT_SemVer() { Initialize(); }

    [OnDeserializing]
    private void Initialize(StreamingContext context = default) { }

    [DataMember(Name = "Major", IsRequired = true, Order = 1)]
    public byte Major { get; set; }

    [DataMember(Name = "Minor", IsRequired = true, Order = 2)]
    public byte Minor { get; set; }

    [DataMember(Name = "Patch", IsRequired = true, Order = 3)]
    public byte Patch { get; set; }

    // TypeId must match the DataType NodeId on the server.
    // The "DT_" prefix is a Siemens S7 OPC UA convention for data type nodes;
    // the quoted name is the Siemens-specific identifier format.
    public ExpandedNodeId TypeId =>
        new ExpandedNodeId(
            "nsu=http://www.siemens.com/simatic-s7-opcua;s=DT_\"UDT_SemVer\"");

    // BinaryEncodingId must match the Binary Encoding NodeId on the server.
    // The "TE_" prefix is the Siemens S7 OPC UA convention for type encoding nodes.
    public ExpandedNodeId BinaryEncodingId =>
        new ExpandedNodeId(
            "nsu=http://www.siemens.com/simatic-s7-opcua;s=TE_\"UDT_SemVer\"");

    public ExpandedNodeId XmlEncodingId => ExpandedNodeId.Null;

    public void Encode(IEncoder encoder)
    {
        encoder.WriteByte("Major", Major);
        encoder.WriteByte("Minor", Minor);
        encoder.WriteByte("Patch", Patch);
    }

    public void Decode(IDecoder decoder)
    {
        Major = decoder.ReadByte("Major");
        Minor = decoder.ReadByte("Minor");
        Patch = decoder.ReadByte("Patch");
    }

    public bool IsEqual(IEncodeable encodeable) =>
        encodeable is UDT_SemVer other &&
        Major == other.Major && Minor == other.Minor && Patch == other.Patch;

    public void EncodeJson(IJsonEncoder encoder)
    {
        encoder.WriteByte("Major", Major);
        encoder.WriteByte("Minor", Minor);
        encoder.WriteByte("Patch", Patch);
    }

    public void DecodeJson(IJsonDecoder decoder)
    {
        Major = decoder.ReadByte("Major");
        Minor = decoder.ReadByte("Minor");
        Patch = decoder.ReadByte("Patch");
    }

    public object Clone() => MemberwiseClone();
}

Important: BinaryEncodingId must match the Binary Encoding NodeId returned by the server (visible in the OPC UA address space as the DataTypeEncodingType child node named "Default Binary"). This is what the decoder uses to look up the registered type.

Step 2 – Register the Type Before Reading

Register the type with the session's factory before reading any values that use it. The simplest way is to add the Type directly:

// Create and connect the session
var session = await Session.Create(...);

// Register the custom type with the session's encodeable factory
session.Factory.Builder
    .AddEncodeableType(typeof(UDT_SemVer))
    .Commit();

// Now read – the stack decodes the ExtensionObject automatically
DataValue result = await session.ReadValueAsync(
    "ns=3;s=\"H35dispenser\".\"ID\".\"ElectricalVersion\"");

if (result.WrappedValue.TryGetValue(out ExtensionObject extObject) &&
    extObject.Body is UDT_SemVer semVer)
{
    Console.WriteLine($"Major={semVer.Major} Minor={semVer.Minor} Patch={semVer.Patch}");
}

You can also register all types from an entire assembly at once:

session.Factory.Builder
    .AddEncodeableTypes(typeof(UDT_SemVer).Assembly)
    .Commit();

Or register multiple types individually in a single builder chain:

session.Factory.Builder
    .AddEncodeableType(typeof(UDT_SemVer))
    .AddEncodeableType(typeof(UDT_AnotherType))
    .Commit();

Note: ComplexTypeSystem.LoadAsync() is not required when using this approach. If you call LoadAsync() after registering your own types, the ComplexTypeSystem will skip types that are already registered in the factory.

Approach 2: Source-Generated IEncodeable (Recommended for New Code)

Starting with version 2.0, you can annotate a POCO class with [DataType] and optional [DataTypeField] attributes and the OPC UA source generator will automatically generate the IEncodeable implementation for you. This eliminates the need to hand-write Encode, Decode, IsEqual, and Clone methods.

See Source-Generated Data Types for full details.

using Opc.Ua;

[DataType(Namespace = "http://www.siemens.com/simatic-s7-opcua",
          BinaryEncodingId = "s=TE_\"UDT_SemVer\"")]
public partial class UDT_SemVer
{
    [DataTypeField(Order = 1)]
    public byte Major { get; set; }

    [DataTypeField(Order = 2)]
    public byte Minor { get; set; }

    [DataTypeField(Order = 3)]
    public byte Patch { get; set; }
}

After adding the source generator NuGet package, the generated registration extension method can be used:

session.Factory.Builder
    .AddMyNamespaceDataTypes()
    .Commit();

Approach 3: Runtime IStructure (No Pre-defined Types Required)

If you do not know the type structure at compile time, or prefer not to create .NET types for every server type, use ComplexTypeSystem to load the type definitions at runtime and access fields via the IStructure interface. This requires no hand-written types.

See the Basic Usage and Advanced Usage sections below for examples.

Advanced Usage

Loading Specific Types

Instead of loading all types, you can load specific types or namespaces:

Load a Specific Type

var complexTypeSystem = new ComplexTypeSystem(session);

// Load a specific type by NodeId
ExpandedNodeId typeNodeId = new ExpandedNodeId("ns=2;i=3001");
IType? systemType = await complexTypeSystem.LoadTypeAsync(typeNodeId);

if (systemType != null)
{
    Console.WriteLine($"Loaded type: {systemType.XmlName}");
}

Load a Specific Type with Subtypes

// Load a type and all its subtypes
ExpandedNodeId typeNodeId = new ExpandedNodeId("ns=2;i=3001");
IType? systemType = await complexTypeSystem.LoadTypeAsync(typeNodeId, subTypes: true);

Load All Types from a Namespace

var complexTypeSystem = new ComplexTypeSystem(session);

// Load all custom types from a specific namespace
string namespaceUri = "http://mycompany.com/MyCustomTypes";
bool success = await complexTypeSystem.LoadNamespaceAsync(namespaceUri);

if (success)
{
    Console.WriteLine($"Successfully loaded types from namespace: {namespaceUri}");
}

Working with Complex Type Properties

The IStructure interface provides flexible access to complex type fields:

Access by Name

if (extensionObject.Body is IStructure complexType)
{
    // Get property value by name
    Variant value = complexType["PropertyName"];

    // Set property value by name
    complexType["PropertyName"] = newValue;
}

Access by Index

if (extensionObject.Body is IStructure complexType)
{
    // Get property value by index
    Variant value = complexType[0];

    // Set property value by index
    complexType[0] = newValue;
}

Enumerate Properties

if (extensionObject.Body is IStructure complexType)
{
    // Enumerate with detailed information
    foreach (IStructureField property in complexType.GetFields())
    {
        Console.WriteLine($"Property: {property.Name}");
        Console.WriteLine($"  Type: {property.TypeInfo}");
        Console.WriteLine($"  IsOptional: {property.IsOptional}");
        Console.WriteLine($"  Value: {complexType[property.Name]}");
    }
}

Handling Enumeration Types

Custom enumerations are also supported:

// After loading the type system, enum values are automatically decoded
DataValue dataValue = await session.ReadValueAsync(enumNodeId);

if (dataValue.WrappedValue.TryGetValue(out EnumValue enumValue))
{
    // The value is the numeric representation
    Console.WriteLine($"Enum value: {enumValue}");

    // You can also get the enum type from the factory
    ExpandedNodeId enumTypeId = ...;
    if (session.Factory.TryGetEnumeratedType(enumTypeId, out IEnumeratedType enumType))
    {
        Console.WriteLine($"Enum type: {enumType.XmlName}");
    }
}

Type Information and Introspection

Get All Loaded Types

var complexTypeSystem = new ComplexTypeSystem(session);
await complexTypeSystem.LoadAsync();

// Get all types that were dynamically created
IReadOnlyList<XmlQualifiedName> definedTypes = complexTypeSystem.GetDefinedTypes();

foreach (XmlQualifiedName type in definedTypes)
{
    Console.WriteLine($"Type: {type.Namespace}.{type.Name}");
}

Get Type Definitions

// Get the DataTypeDefinition for a specific type
ExpandedNodeId dataTypeId = new ExpandedNodeId("ns=2;i=3001");
var definitions = complexTypeSystem.GetDataTypeDefinitionsForDataType(dataTypeId);

foreach (var kvp in definitions)
{
    Console.WriteLine($"NodeId: {kvp.Key}");
    Console.WriteLine($"Definition: {kvp.Value}");
}

Get Loaded Data Type IDs

// Get all NodeIds for loaded data types
IEnumerable<ExpandedNodeId> dataTypeIds = complexTypeSystem.GetDefinedDataTypeIds();

foreach (var dataTypeId in dataTypeIds)
{
    Console.WriteLine($"Loaded type: {dataTypeId}");
}

Using Custom Type Factories

You can provide a custom type factory for advanced scenarios:

// Create a custom factory (implement IComplexTypeFactory)
IComplexTypeFactory customFactory = new MyCustomComplexTypeFactory();

// Use it with the ComplexTypeSystem
var complexTypeSystem = new ComplexTypeSystem(session, customFactory);
await complexTypeSystem.LoadAsync();

Working with Telemetry and Logging

The ComplexTypeSystem supports the OPC UA telemetry context for observability:

// Use the session's telemetry context (default)
var complexTypeSystem = new ComplexTypeSystem(session);

// Or provide a custom telemetry context
ITelemetryContext telemetry = myCustomTelemetryContext;
var complexTypeSystem = new ComplexTypeSystem(session, telemetry);

// The system will log type loading information
await complexTypeSystem.LoadAsync();

Common Patterns

Pattern 1: One-Time Type Loading at Session Start

public async Task<ISession> CreateSessionWithTypes(string endpointUrl)
{
    var session = await Session.Create(
        configuration,
        new ConfiguredEndpoint(null, new EndpointDescription(endpointUrl)),
        false,
        "MyClient",
        60000,
        null,
        null
    );

    // Load all custom types immediately after connection
    var complexTypeSystem = new ComplexTypeSystem(session);
    await complexTypeSystem.LoadAsync();

    return session;
}

Pattern 2: Lazy Loading on Demand

public class OpcUaClient
{
    private ISession _session;
    private ComplexTypeSystem _complexTypeSystem;
    private bool _typesLoaded;

    public async Task EnsureTypesLoadedAsync()
    {
        if (!_typesLoaded)
        {
            _complexTypeSystem = new ComplexTypeSystem(_session);
            await _complexTypeSystem.LoadAsync();
            _typesLoaded = true;
        }
    }

    public async Task<DataValue> ReadComplexValueAsync(NodeId nodeId)
    {
        await EnsureTypesLoadedAsync();
        return await _session.ReadValueAsync(nodeId);
    }
}

Pattern 3: Reading Multiple Complex Values

public async Task ReadMultipleComplexValuesAsync(IList<NodeId> nodeIds)
{
    // Load types once
    var complexTypeSystem = new ComplexTypeSystem(session);
    await complexTypeSystem.LoadAsync();

    // Read all values
    var nodesToRead = nodeIds.Select(id => new ReadValueId
    {
        NodeId = id,
        AttributeId = Attributes.Value
    }).ToList();

    var response = await session.ReadAsync(
        null,
        0,
        TimestampsToReturn.Both,
        new ReadValueIdCollection(nodesToRead),
        CancellationToken.None
    );

    // Process results
    for (int i = 0; i < response.Results.Count; i++)
    {
        var dataValue = response.Results[i];
        if (dataValue.WrappedValue.TryGetValue(out ExtensionObject extensionObject) &&
            extensionObject.Body is IStructure complexType)
        {
            Console.WriteLine($"NodeId: {nodeIds[i]}");
            foreach (IStructureField property in complexType.GetFields())
            {
                Console.WriteLine($"  {property.Name}: {complexType[property.Name]}");
            }
        }
    }
}

Error Handling

Handling Type Loading Failures

try
{
    var complexTypeSystem = new ComplexTypeSystem(session);
    bool success = await complexTypeSystem.LoadAsync(throwOnError: true);

    if (success)
    {
        Console.WriteLine("All types loaded successfully");
    }
    else
    {
        Console.WriteLine("Some types could not be loaded");
    }
}
catch (ServiceResultException ex)
{
    Console.WriteLine($"Failed to load types: {ex.Message}");
    // Handle error appropriately
}

Handling Missing Type Definitions

// Try to load a specific type
var complexTypeSystem = new ComplexTypeSystem(session);
IType? systemType = await complexTypeSystem.LoadTypeAsync(typeNodeId, throwOnError: false);

if (systemType == null)
{
    Console.WriteLine($"Type {typeNodeId} could not be loaded");
    // Fall back to reading as ExtensionObject with opaque body
}

Performance Considerations

Type System Caching

  • The ComplexTypeSystem loads types once and caches them in the session's factory
  • Subsequent reads/writes use the cached types automatically
  • Types remain available for the lifetime of the session

Minimizing Load Time

// Load only enumerations (faster)
var complexTypeSystem = new ComplexTypeSystem(session);
await complexTypeSystem.LoadAsync(onlyEnumTypes: true);

// Or load only specific namespaces
await complexTypeSystem.LoadNamespaceAsync("http://mycompany.com/MyTypes");

Batch Operations

When reading multiple values with complex types, read them in batches to minimize round-trips:

// Read multiple values in one call
var response = await session.ReadAsync(
    null,
    0,
    TimestampsToReturn.Both,
    new ReadValueIdCollection(nodesToRead),
    CancellationToken.None
);

Troubleshooting

Types Not Loading

Problem: LoadAsync() completes but types are not available

Solutions:

  • Verify the server supports DataTypeDefinition or provides type dictionaries
  • Check server logs for encoding/dictionary availability
  • Use verbose logging to see what types are discovered
// Enable detailed logging through telemetry context
var telemetry = session.MessageContext.Telemetry;
var complexTypeSystem = new ComplexTypeSystem(session, telemetry);

// The ComplexTypeSystem will log detailed information during type loading
await complexTypeSystem.LoadAsync();

Values Still Encoded as ExtensionObject

Problem: Values are read as ExtensionObject with opaque body instead of structured types

Solutions:

  • If using ComplexTypeSystem: ensure LoadAsync() was called before reading the value, verify the type is actually loaded with complexTypeSystem.GetDefinedTypes(), and check if the server's type definition is complete and valid.
  • If using a hand-written IEncodeable (Approach 1): ensure the type is registered with session.Factory.Builder.AddEncodeableType(typeof(YourType)).Commit() before reading. The BinaryEncodingId on your type must exactly match the Binary Encoding NodeId reported by the server — use a generic OPC UA client (e.g. UA Expert) to inspect the correct NodeId.
  • If using source-generated types (Approach 2): ensure the generated Add...DataTypes() extension method is called on session.Factory.Builder before reading.

Performance Issues

Problem: Type loading takes too long

Solutions:

  • Load only required namespaces instead of all types
  • Load types once at session start rather than on-demand
  • Consider caching type information across sessions if reconnecting frequently

Server-Side Complex Types

Servers can build the same dynamic stand-in encodeables for the custom DataTypes in their address space. This is useful when a server loads a NodeSet2 at runtime whose DataTypes were never compiled into a .NET type: without a matching encodeable the server cannot encode or decode instances of those DataTypes. Server-side complex types prime the server's IEncodeableFactory with stand-ins built from the DataTypeDefinition attribute of every custom DataType, reusing exactly the same NativeAOT friendly path as the client (ComplexTypeSystem, in Opc.Ua.Core.Schema). This runs by default in StandardServer (controlled by LoadComplexTypes).

DataTypes that are already backed by a compiled, source-generated type are already registered in the server's IEncodeableFactory and used as-is for encoding and decoding; the server only builds stand-ins for the DataTypes that are still missing from the factory (i.e. those loaded from a NodeSet at runtime).

If you are using Runtime NodeSets, the server-side complex-type pass runs automatically after startup imports and before each live lifecycle generation is published. No extra configuration is needed. See RuntimeNodeSets.md for startup and live add/reload/remove semantics, compatible DataType rules, and the stream ownership contract.

How compiled types reach the factory

Compiled DataTypes are registered explicitly, not by reflection: the OPC UA source generator emits one Add<Namespace>(this IEncodeableFactoryBuilder) extension per namespace, and a node manager calls it while it builds its address space (for example Server.Factory.Builder.AddTestData().Commit()). Node managers finish starting before OnNodeManagerStartedAsync runs, so every source-generated type is already present in server.Factory when the complex-type pass executes — ComplexTypeSystem finds them via TryGetType / TryGetEncodeableType and skips them, creating stand-ins only for the remaining runtime-loaded DataTypes.

Configuring via dependency injection (recommended)

Complex-type loading is on by default. Use the fluent AddComplexTypeSystem() extension when configuring the hosted server to tune the pass and expose the primed factory as a DI-resolvable schema IDataTypeDefinitionResolver:

using Microsoft.Extensions.DependencyInjection;

builder.Services
    .AddOpcUa()
    .AddServer(options => { /* ... */ })
    .AddNodeManager<MyRuntimeNodeSetNodeManagerFactory>()
    .AddComplexTypeSystem();  // build stand-ins for runtime-loaded DataTypes

The pass runs once, after the address space is fully built and before the server starts accepting connections, so clients never observe a window where custom values cannot be decoded. The primed IEncodeableFactory is also exposed as the schema IDataTypeDefinitionResolver (via EncodeableFactoryDefinitionSource), so schemas can be produced directly from the factory — no separate registry population or address-space walk is required. If a DataTypeDefinitionRegistry is registered (for example by AddSchemaGeneration() for schema-only types that have no encodeable), it is composed as a fallback.

Options can be configured:

.AddComplexTypeSystem(options =>
{
    options.Enabled = true;        // load complex types on startup (default)
    options.OnlyEnumTypes = false; // also build structured types (default)
    options.ThrowOnError = false;  // log and continue on failures (default)
});

Direct usage without dependency injection

For servers that are not hosted through dependency injection, no extra type is required: StandardServer loads complex types by default (LoadComplexTypes), so a plain instance already builds the stand-ins once its address space is available:

var server = new StandardServer(telemetry);
await application.StartAsync(server);

Opt out by setting server.LoadComplexTypes = false before starting. To customize the pass — for example to load only enumerations — override OnNodeManagerStartedAsync in a StandardServer subclass and drive it yourself instead of calling base (which would run the default pass):

protected override async ValueTask OnNodeManagerStartedAsync(
    IServerInternal server, CancellationToken cancellationToken)
{
    var options = new ServerComplexTypeOptions { OnlyEnumTypes = true };
    await server
        .LoadComplexTypesAsync(server.Telemetry, options, cancellationToken: cancellationToken)
        .ConfigureAwait(false);
}

IServerInternal.LoadComplexTypesAsync(...) can also be invoked directly on a running server to (re)build the stand-ins on demand. It drives the shared ComplexTypeSystem with an AddressSpaceComplexTypeResolver that surfaces the server's DataType nodes and their DataTypeDefinition attributes, and returns an IDataTypeDefinitionResolver backed by the primed factory. Because the runtime stand-ins (and the generated types) expose their definition via IDataTypeDefinitionSource, the encodeable factory itself is the source of truth for data type definitions — the DataTypeDefinitionRegistry is only needed for schema-only types that have no encodeable.

API Reference

ComplexTypeSystem Class

The main class for managing complex types.

Constructors

// The ComplexTypeSystem type is defined in Opc.Ua.Core.Schema (namespace Opc.Ua).

// Create with a complex type resolver and telemetry (uses the default DefaultComplexTypeFactory)
ComplexTypeSystem(IComplexTypeResolver complexTypeResolver, ITelemetryContext telemetry)

// Create with a resolver, a custom type builder factory and telemetry
ComplexTypeSystem(IComplexTypeResolver complexTypeResolver, IComplexTypeFactory complexTypeBuilderFactory, ITelemetryContext telemetry)

// Client factory helpers (Opc.Ua.Client, namespace Opc.Ua.Client.ComplexTypes) bind a
// ComplexTypeSystem to a session using the session node cache as the resolver:

// Uses the default, NativeAOT friendly type builder
static ComplexTypeSystem ComplexTypeSystem.Create(ISession session, ITelemetryContext telemetry)

// Uses a caller-provided type builder, e.g. the Reflection.Emit ComplexTypeBuilderFactory
// (requires the OPCFoundation.NetStandard.Opc.Ua.Client.ComplexTypes package)
static ComplexTypeSystem ComplexTypeSystem.Create(ISession session, IComplexTypeFactory complexTypeBuilderFactory, ITelemetryContext telemetry)

Methods

// Load all custom types from the server
ValueTask<bool> LoadAsync(bool onlyEnumTypes = false, bool throwOnError = false, CancellationToken ct = default)

// Load a specific type with optional subtypes
Task<IType?> LoadTypeAsync(ExpandedNodeId nodeId, bool subTypes = false, bool throwOnError = false, CancellationToken ct = default)

// Load all types from a namespace
Task<bool> LoadNamespaceAsync(string ns, bool throwOnError = false, CancellationToken ct = default)

// Get all dynamically created type names
IReadOnlyList<XmlQualifiedName> GetDefinedTypes()

// Get all loaded data type NodeIds
IEnumerable<ExpandedNodeId> GetDefinedDataTypeIds()

// Get data type definitions for a type
NodeIdDictionary<DataTypeDefinition> GetDataTypeDefinitionsForDataType(ExpandedNodeId dataTypeId)

// Clear the data type cache
void ClearDataTypeCache()

Properties

// Get the loaded data type dictionaries
NodeIdDictionary<DataDictionary> DataTypeSystem { get; }

IStructure Interface

Interface for accessing properties of complex types.

// Access property by zero-based index
Variant this[int index] { get; set; }

// Access property by name
Variant this[string name] { get; set; }

// Get property names
IReadOnlyList<IStructureField> GetFields()

IStructureField Interface

Provides metadata about a property in a complex type.

string Name { get; }                      // Property name
bool IsOptional { get; }                  // Whether field is optional
TypeInfo TypeInfo { get; }                // Type info of the field

Known Limitations

  1. OptionSet Support: Concrete Structure-backed sub-types of the abstract OptionSet DataType (i=12755, e.g. AccessRights, CarExtras) are automatically registered by the default ComplexTypeSystem builder as Opc.Ua.Encoders.OptionSet runtime instances, driven by either the EnumDefinition carried in DataTypeDefinition or a fallback synthesized from the OptionSetValues property. The runtime class exposes the two canonical Value / ValidBits ByteStrings plus bit accessors keyed by field name or bit index. Per Part 3 §8.40 / §3.2.8, the overall ByteString length is fixed by the sub-type's declared bits (exposed as ByteLength); setting a bit outside that range throws ArgumentOutOfRangeException. Remaining limitations:
    • UInteger-backed OptionSet DataTypes (DataTypes deriving from an unsigned integer with IsOptionSet=true) continue to be represented as their underlying unsigned integer in a Variant — no per-bit metadata is surfaced.
    • The legacy Reflection.Emit builder in Opc.Ua.Client.ComplexTypes throws NotSupportedException for OptionSet sub-types; switch to the default builder (ComplexTypeSystem.Create(session, telemetry)) for OptionSet support.
  2. Legacy Dictionary Support: Some OPC UA 1.03 structured types that cannot be mapped to OPC UA 1.04 definitions are ignored
  3. Type Modifications: Once loaded, types cannot be dynamically updated during a session. Reconnect to reload modified types.

Additional Resources

See Also